We deliver to Europe! | E-Mail: info@omtec.de | Contact form

I-87018ZW-G/S

Productfeatures ICP DAS I-87018ZW-G/S

  •     10-ch Thermocouple Input Module
  •     Current Input, Voltage Input and Thermocouple Input
  •     240 Vrms Overvoltage Protection
  •     Individual Channel Configuration
  •     Open Thermocouple Detection
  •     Temperature outputs consistency
  •     Stable temperature output in the field
  •     4 KV ESD Protection
  •     3000 VDC Intra-module Isolation
  •     3750 Vrms Photo Isolation
Sale to corporate customers
Get individual price by e-mail
  • I-87018ZW-G-S
  • ICP DAS
The “Z” version is another milestone in the development of I-87018 and a testament to excellence... more
Product information "I-87018ZW-G/S"

The “Z” version is another milestone in the development of I-87018 and a testament to excellence by ICP DAS R&D team. I-87018ZW is specifically designed for extremely accurate thermocouple measurement. It features automatic compensation for each channel. Current input and voltage input are supported. Another feature is that ten of its input channels can individually be configured with different kinds of analog input. I-87018ZW also got open thermocouple detection and many protection mechanisms.

Related links to "I-87018ZW-G/S"
Available downloads:
CPU Module Watchdog Timer: Yes, Module (1.6 Seconds), Communication (Programmable)... more
CPU Module
  • Watchdog Timer: Yes, Module (1.6 Seconds), Communication (Programmable)
Isolation
  • Intra-module Isolation: 3000 VDC
EMS Protection
  • ESD (IEC 61000-4-2): ± 4 kV Contact for Each Terminal
    ±8 kV Air for Random Point
LED Indicators
  • Status: 1 x Power and Communication
Analog Input
  • Channels: 10
  • Type: Voltage、Current、Thermocouple
  • Sensor Type: (J, K, T, E, R, S, B, N, C, L, M, LDIN43710
  • Temperature Output Consistency: Yes
  • Stable Temperature Output in the Field: Yes
  • Range: +/- 15 mV, +/- 50 mV, +/- 100 mV, +/- 500 mV, +/- 1 VDC, +/- 2.5 VDC
    +/-20 mA, 0 ~ +20 mA, +4 ~ +20 mA (Requires Optional External 125 Ω Resistor)
    Thermocouple (J, K, T, E, R, S, B, N, C, L, M, LDIN43710)
  • Resolution: 16-bit
  • Accuracy: ±0.1% of FSR
  • Sampling Rate: 10 Hz (Total)
  • Bandwidth: 15.7 Hz
  • Input Impedance: >400 kΩ
  • Common Mode Rejection: 150 dB
  • Normal Mode Rejection: 100 dB
  • Overvoltage Protection: 240 Vrms
  • Individual Channel Configuration: Yes
  • Open Wire Detection: Yes
  • Zero Drift: ±0.5 μV/°C
  • Span Drift: ±25 ppm/°C
COM Ports
  • Ports: 1 x RS-485
  • Baud Rate: 1200 to 115200 bps
  • Data Format: N, 8, 1
  • Protocol: DCON
Power
  • Consumption: 1.3 W Max.
Mechanical
  • Dimensions (mm): 30 x 84 x 114 (W x L x H)
Environment
  • Operating Temperature: -25 ~ +75 °C
  • Storage Temperature: -40 ~ +85 °C
  • Humidity: 10 ~ 95% RH, Non-condensing
  • Download PDF Datasheet ICP DAS I-87018ZW-G/S