DeviceMaster UP 4-Port VDC Modbus

Productfeatures Korenix DeviceMaster UP 4

  • Serial to Modbus/TCP
  • Wide operating temperature ranges (-37°C to 74°C)
  • Variable power input eliminates need for power converters
  • PortVision® enterprise monitoring and management software
  • RoHS Directive 2002/95/EC compliant
  • DualConnectPlus™ Technology
Sale to corporate customers
Get individual price by e-mail
  • DeviceMaster-UP-4
  • Comtrol
1-Port serial device server with DB9 connectors and one Ethernet port. Simultaneously... more
Product information "DeviceMaster UP 4-Port VDC Modbus"

1-Port serial device server with DB9 connectors and one Ethernet port.

Simultaneously connect both serial and Modbus devices to PLCs and/or applications. Or The DeviceMaster UP brings plant floor device visibility by enabling communications between factory floor serial and Modbus devices, and PLC controllers.

  • DIN-rail mounting and screw terminal power connections
  • Highly flexible and unique Modbus functionality
  • Multiple Modbus master and slave types
  • Raw/ASCII Serial and Ethernet device support
  • Variable power input eliminates need for power converters
  • Dual Ethernet ports for daisy chaining network connections between multiple units
  • RoHS 2 compliant under CE

Pepperl+Fuchs Comtrol has developed three unique Modbus firmware applications that provide a wide range of Modbus connectivity. Simple connections or complex Modbus networks, you can do it all with a DeviceMaster UP. The DeviceMaster UP is loaded with Modbus Router firmware but you can load either Modbus TCP or Modbus Server, depending on your requirements.

The DeviceMaster UP has been designed to meet the demands of today’s increasingly diverse Modbus installations.

Highly flexible and robust, the DeviceMaster UP provides connectivity between a vast array of Modbus controllers and devices. Simplified configuration pages, innovative functionality and informative diagnostic information all make for quick and easy set-up of even the most complex Modbus installations.

Related links to "DeviceMaster UP 4-Port VDC Modbus"
Available downloads:
Hardware Bus Interface Specification 10/100 BASE-T Memory SDRAM... more
Hardware
Bus Interface Specification
  • 10/100 BASE-T
Memory
  • SDRAM - 32 MB
  • Flash - 8 MB
Enclosure
  • Black Powder Coated Finished Steel
Installation Method
  • Panel mountable
LED Indicators
  • 100Mb Ethernet
  • Collision
  • Ethernet Link/Activity
  • Device Status
  • RX/TX Per Port
Dimensions (LxWxH)
  • 10.8" x 6.3" x 1.5" - 275 x 160 x 38.1 mm
Product Weight
  • 3.3 lbs - 1.50 kg
Electrical Specifications
Input Voltage Requirements
  • 9 - 30 VDC
External Power Consumption (max.)
  • 3.0 Watts
  • Input: 90 - 264VAC @ 47-63Hz
  • Output: 24 VDC @ 1A
ESD Surge Protection
  • Provides minimum of 15KV for a duration of 1ns @ 200A. All Ethernet components are rated to 1.5KV magnetic surge protection in addition to the surge protection levels specified.
Environmental Specifications
Operating Temperature
  • -37° to 74°C
Storage Temperature
  • -40° to 85°C
Humidity (non-condensing)
  • System On: 20% to 80%
  • System Off: 8% to 80%
Altitude
  • 0 to 10000 Feet
Heat Output
  • 8.5 BTU/Hr
MTBF (Mean Time Between Failures)
  • 25.0 Years
Serial Communications
Software Selectable
  • RS-232/422/485
Serial Data Control
  • Data Bits: 5, 6, 7 or 8
  • Parity: odd, even, or none
  • Stop Bits: 1, 1.5, or 2
  • Flow Control: None, RTS/CTS, XON/XOFF, or Half-duplex
Communication Modes
  • Modbus/TCP to Serial or Ethernet TCP/IP
  • Modbus/TCP to Modbus/RTU
  • Modbus/TCP to raw serial data
  • Modbus/RTU Device (Auto Locate and Auto Route)
Network Protocols
  • Telnet
  • HTTP
  • SNMP
  • DHCP
  • ARP
  • BOOTP
  • Ping
Modbus Router Features (Default)
Description
  • Pure Modbus, multiple Modbus master and slave types , remote, local, and private devices
Supported Interfaces
  • PLCs, SCADA systems, HMIs, OPC servers and applications
Web Page Configuration
  • Master-to-master connectivity via the Shared Memory sub-system
  • Private Modbus serial bus support designed to restrict access to private Modbus devices
  • Connectivity from serial Modbus masters to Modbus/TCP networks
  • The ability to connect multiple types of Modbus masters to Modbus slave device(s)
  • Convert from one form of Modbus, such as Modbus/TCP, to Modbus/RTU or Modbus/ASCII
  • Provide connectivity from a serial Modbus master to a remote Modbus slave device
  • Eliminate Modbus device ID conflicts and solve device ID configuration problems
  • Enable Modbus security by blocking write messages in Read-Only Mode
  • Device ID to Modbus/TCP slave via configurable IP address and TCP/IP port
  • Modbus Network Bridging support
Diagnostics
  • Local and remote slave device and port specific diagnostic web pages that display status, message response timing, timeout and other error counts, and overall message statistics. A serial log is also included to provide message level diagnosis.
Modbus Server Features (Downloadable)
Description
  • Modbus/RTU over Ethernet master(s) to serial slave(s)
Supported Interfaces
  • OPC Servers and Applications that require Modbus/RTU communication over Com ports or Ethernet TCP/IP connections
Web Page Configuration
  • Supports Modbus/RTU over Ethernet TCP/IP connections to the corresponding serial port via intelligent Modbus message handling and routing.
  • Supports only Modbus/RTU over Ethernet TCP/IP connections to a serial port. For Modbus/TCP functionality, please see the DeviceMaster UP.
  • Supports up to six Ethernet TCP/IP connections to each serial port.
  • Supports up to 255 Modbus devices per port. Both valid, (1-247), and reserved, (248-255), device ids are supported
  • Modbus/RTU specific message handling: CRC verification of all messages received on the TCP/IP and serial interfaces
  • Timing out of responses from slave Modbus/RTU devices
  • Broadcast message handling on connected port only
  • System monitoring to ensure gateway operation:
  • Gateway busy
  • Application message timeouts
  • Combined with a serial port redirector, such as the Comtrol Secure Port Redirector, can support up to six COM port connections to each serial port
Diagnostics
  • Modbus device specific statistics, response timing, and status. Up to 255 devices per serial port can be monitored simultaneously.
  • Serial port specific statistics and status
  • Serial port message logging
Modbus/TCP Features (Downloadable)
Supported Interfaces
  • PLC, SCADA system, HMI, or OPC Server
Supported Controllers
  • Modbus/TCP masters and slaves
  • Modbus/RTU and Modbus/ASCII serial masters and slaves
  • Applications over Ethernet TCP/IP connections (raw/ASCII only)
Supported Devices
  • Raw/ASCII devices, both serial and Ethernet TCP/IP, such as barcode scanners, vision systems, RFID readers, weigh scales, encoders and printers
  • Modbus/RTU and Modbus/ASCII serial slaves
Recommended Installations
  • Connectivity to serial and/or Ethernet TCP/IP raw/ASCII devices
  • Connectivity to Modbus/RTU and/or Modbus/ASCII serial devices
  • Connecting single or multiple Modbus masters and/or applications to the devices
  • Automatic Modbus protocol translations (if needed)
Web Page Configuration
  • Highly flexible, with an emphasis on Raw/ASCII devices
  • Also supports Modbus RTU/ASCII slave devices
  • Connect Raw/ASCII devices to Modbus/TCP and Modbus RTU/ASCII serial controllers
  • Automatic protocol conversions and routing
  • Connect Modbus/TCP and Modbus RTU/ASCII serial masters to Modbus RTU/ASCII serial slaves
  • Many unique Raw/ASCII handling features
  • Simultaneously connect multiple Modbus masters to individual devices
  • Modbus message Alias Device ID conversions
Diagnostics
  • Yes
Sample PLC Programs
  • Yes
Regulatory Approval Marks
CE Mark, FCC Part 15 Subpart B Class A, CTick, CUL, ODVA Certified, PIC Certified, RoHS Certified
Regulatory Approvals
Emissions
  • EN55022 & A1:2000 IEC 100032
  • IEC 100033
  • CISPR22
  • ICES003
Immunity
  • EN55024
  • EN6100042
  • EN6100043
  • EN6100044
  • EN6100045
  • EN6100046
  • EN6100048
  • EN61000411
  • IEC 100042
  • IEC 100043
  • IEC 100044
  • IEC 100045
  • IEC 100046
  • IEC 100048
  • IEC 1000411
Safety
  • EN60950
  • IEC 60950
  • CSA C22.2 No. 50/UL60950
Other Regulatory Approvals
  • European Standard: RoHS 2 Compliant under CE
Pinout Diagram
Ground must be tied to signal ground. Pin Layout
  • Download PDF Datasheet Korenix DeviceMaster UP 4